FLAMPROOF (EXPLOSION-PROOF) PROTECTION (Ex ‘d’)
Maximum gaps and flame path for gas groups depends on ignition energies of the gas / vapour and the volume of the enclosure
For example, for IIB gas group, for 100 Cubic cm volume, for flanged joints:
- Flame Path - 6 mm
- Maximum Gap - 0.3 mm
-
For II C Hydrogen, 100 cubic cm volume, for flanged joints:
- Flame path - 9.5 mm
- Maximum Gap - 0.1 mm